ZN23-40.5 indoor high voltage vacuum circuit breaker

ZN23-40.5 indoor high voltage vacuum circuit breaker
Product Detailed

1.vacuum circuit breaker with IEC standard
2.Reliable and maintenance free
3.Type: Vacuum
4.Provide OEM service

     ZN23-40.5 indoor high voltage vacuum circuit breaker is the indoor installation in 35kv,50Hz three phase current system. They are applicable to control and protect of high-voltage electromotor, transformer, capacitor in mining industrial enterprise, power station, transformer substation.

The strength is

 1.Non-contamination, non-fire hazard, non-exploration;

2.Long mechanical life;

3. Nearly no need to maintain

4.Can be frequent operated. Both type CT19BN spring operating structure or the CD10III electromagnetic operating structure can be chosen.

This type of product conforms to the requirement of GB1984-89 and DL402-91standard for alternating current high voltage circuit breaker.

 

Ambient condition

1 Ambient temperature: max +40°C min -15°C(conveyance under -30°C is allowed)

2 Altitude: ≤1000m

3 Relative humidity: daily average relative humidity: ≤95%; monthly average relative humidity≤90%, daily average saturated vapor pressure ≤2.2*10-3 MPa,monthly average value   ≤1.8*10-3 MPa

4 Earthquake intensity: ≤8 degree

5 The installation should be free from fire, explosion, severe vibration, chemical corrosion and serious pollution

 

Order instruction

Complete model and order quantity of the product

Rated current and rated voltage

Rated short circuit breaking current, operation voltage

Required accessory and quantity, rated voltage of open and close coil

Other requirement please contact with us directly

 

Main Technical Data    
Rated voltage                                                             kv40.5
Rated frequency                                                         Hz50
Rated lighting impulse withstand voltagekv185
Rated short-time power frequency withstand voltage (dry)   kv95
Rated short-time power frequency withstand voltage(humid)    kv80
Rated current                                                             A125016002000
Rated short-circuit breaking current                              kA202531.5
Rated short-circuit making current                               kA506380
Rated short-time withstand current                         kA202531.5
Rated peak withstand current                               kA506380
Rated operations of short-circuit breaking current interruption   times20
Full opening times0.1
Rated operating sequence                                             0-0.3-CO-180s -CO
Rated duration of short-circuit                              s4
Rated single capacitor bank breaking current                  A400
Contact erosion limit                                       mm3
Closing time ms50~100
Opening time ms30~60
Mechanical life                                           times12000
     
Note:Rated characteristics can be given on requirment   